Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Dent Mater J ; 43(1): 126-135, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38072410

RESUMO

The objective of the study was to evaluate the effects of dentin deproteinization protocols for post space using different formulations containing sodium hypochlorite before fiber post cementation with self-adhesive resinous cement. The groups were divided according to the irrigation protocol (DWC, SHS, SHT and SHG). The residue cleanliness, bond strength, adhesive failure pattern, and tag formation at the adhesive interface between the self-adhesive cement and the dentin were evaluated. For this, analysis in scanning electron microscope, push-out test and confocal laser scanning microscopy were performed. The SHT protocol showed the highest residue cleanliness on the dentin surface of the post space (p<0.05). In addition, SHT protocol showed highest bond strength and tag formation in the cervical and middle thirds (p<0.05). Dentin deproteinization with sodium hypochlorite with surfactant provided the best dentin cleaning of residues, bond strength and tag formation after cementation of the fiber post with self-adhesive cement.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentação/métodos , Tensoativos/farmacologia , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/química , Cimentos de Resina/química , Dentina , Teste de Materiais
2.
Dent Mater J ; 43(1): 112-118, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38072411

RESUMO

This study evaluated the influence of different translucent resins (Z350 and Opallis) for customizing fiber posts and light-curing the cementation system using different LED equipment (V, Valo or R, Radii-Cal) on the bond strength and adhesive failure pattern at 24 h and 6 months. Eighty roots were prepared and divided into 4 groups (n=20): ZV (Z350 resin and LED Valo), ZR (Z350 resin and LED Radii-Cal), OV (Opallis resin and LED Valo), OR (Opallis resin and LED Radii-Cal). After post space preparation, the fiber post was customized and cemented with self-adhesive cement and light-curing using V or R LED equipment. Bond strength values were submitted to 2-way ANOVA test. ZV and ZR showed higher bond strength values than the other groups at 6 months of evaluation (p<0.05). The Z350 resin has a favorable influence on the bond strength of self-adhesive cement to root dentin, regardless of the LED polymerization equipment used.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Resinas Compostas/química , Cimentação , Cimentos de Resina/química , Dentina , Teste de Materiais , Vidro/química
3.
Dent Mater J ; 42(6): 878-885, 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-37793825

RESUMO

The study evaluated the persistence of residues, bond strength and tags formation of a cementation system after post-space irrigation with different sodium hypochlorite-based irrigants. The groups were divided according to the irrigation protocol (DW: distilled water; SHS: sodium hypochlorite solution; SHG: sodium hypochlorite gel; and, SHT: sodium hypochlorite with surfactant). Forty roots (n=10) were used to evaluate the persistence of residues by scanning electron microscopy. Other forty roots were used to the push-out bond strength test, failure mode and tag formation analyses. Non-parametric data were submitted to Kruskal Wallis and Dunn tests, while parametric data were evaluated by one-way ANOVA. No difference was observed in the persistence of residues. DW showed the highest bond strength and tag formation. Type 2 failure mode was the most frequent in the experimental groups. Compared to control, SHT showed the best performance, since less negative effects on adhesive interface was observed.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentação/métodos , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/química , Dentina , Irrigantes do Canal Radicular , Cimentos de Resina/química , Teste de Materiais
4.
Dent Mater J ; 42(5): 654-658, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37460305

RESUMO

This study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10- 15- and 30-min. Statistical analysis was performed using the two-way repeated measures ANOVA test and Bonferroni post-hoc test was used at a significance level of 5%. HP35 and HP15 showed greater temperature variation than HP6 up to 10 min of surface evaluation, showing no differences between them. In the intra-pulpal evaluation, no group showed differences throughout the procedure.


Assuntos
Clareadores Dentários , Clareamento Dental , Humanos , Temperatura , Peróxido de Hidrogênio , Luz , Lasers
5.
J Biomech Eng ; 145(9)2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37195691

RESUMO

Short dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.


Assuntos
Implantes Dentários , Humanos , Estresse Mecânico , Análise de Elementos Finitos , Mandíbula/cirurgia , Análise do Estresse Dentário
6.
J Mater Sci Mater Med ; 34(5): 21, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37118367

RESUMO

High implant survival rates have been achieved in recent decades due to continual modifications in implant design and surface topography, however there is still an ongoing quest to control peri-implant bone loss. The objective of this work was to develop Ti-35Nb-7Zr-5Ta (TNZT) alloys, perform physicochemical and morphological characterization of their surface modified by electrolytic oxidative plasma technique with ions related to osseointegration and lastly evaluate bacterial colonization in vitro. Three groups were evaluated: C group (polished TNZT), CaP group (sodium ß glycerophosphate + calcium acetate) and Mg group (magnesium acetate). Before and after anodizing the surfaces, physicochemical and morphological analyses were performed: scanning electron microscopy with field emission gun (FEG-SEM), energy dispersion spectroscopy (EDS), X-ray diffraction (DRX), wettability (goniometer) and roughness (rugometer). Controlled and treated specimens were contaminated with unstimulated saliva collected from 10 healthy volunteers. Then, biofilm samples were collected and up to 35 microbial species, including commensal and pathogenic microorganisms, were identified and quantified by the Checkerboard DNA-DNA Hybridization method. The CaP group modified the surface morphology in the form of pores, while the Mg group modified it in the form of flakes. The contact angle was significantly smaller in the CaP group. The average roughness was higher in the CaP and Mg groups. A smaller total amount of bacteria was identified in the Mg group and relevant differences were found in the microbial profile associated with different surface treatments. Therefore, considering the microbiological profile and for the prevention of peri-implantitis, the Mg group presented more satisfactory and encouraging results for the manufacture of dental implants.


Assuntos
Cálcio , Implantes Dentários , Humanos , Fosfatos , Magnésio , Ligas/química , Microscopia Eletrônica de Varredura , DNA , Titânio/química , Propriedades de Superfície
7.
Biomed Phys Eng Express ; 8(4)2022 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-35594845

RESUMO

The titanium alloy composition and microdesign affect the dynamic interplay between the bone cells and titanium surface in the osseointegration process. The current study aimed to evaluate the surface physicochemical properties, electrochemical stability, and the metabolic response of the MC3T3-E1 cells (pre-osteoblast cell line) cultured onto titanium-15molybdenum (Ti-15Mo) discs treated with phosphoric acid (H3PO4) and sodium hydroxide (NaOH) and/or strontium-loading by the hydrothermal method. The x-ray dispersive energy spectroscopy (EDS) and x-ray diffraction (XRD) analysis showed no trace of impurities and the possible formation of hydrated strontium oxide (H2O2Sr), respectively. The confocal laser microscopy (CLSM) analysis indicated that titanium samples treated with strontium (Sr) showed greater surface roughness. The acid/alkali treatment prior to the hydrothermal Sr deposition improved the surface free energy and resistance to corrosion of the Ti-15Mo alloy. The acid/alkali treatment also provided greater retention of the Sr particles on the Ti-15Mo surfaces accordingly with inductively coupled plasma optical emission spectrometry (ICP-OES) analysis. The AlamarBlue and fluorescence analysis indicated noncytotoxic effects against the MC3T3-E1 cells, which allowed cells' adhesion and proliferation, with greater cells' spreading in the Sr-loaded Ti-15Mo samples. These findings suggest that Sr deposition by the hydrothermal method has the potential to enhance the physicochemical properties of the Ti-15Mo previously etched with H3PO4and NaOH, and also improve the initial events related to cell-mediated bone deposition.


Assuntos
Estrôncio , Titânio , Ligas/farmacologia , Proliferação de Células , Hidróxido de Sódio/farmacologia , Estrôncio/química , Estrôncio/farmacologia , Propriedades de Superfície , Titânio/química , Titânio/farmacologia
8.
Microorganisms ; 9(10)2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34683474

RESUMO

This study evaluated the microbial colonization (adhesion and biofilm) on modified surfaces of a titanium alloy, Ti-35Nb-7Zr-5Ta, anodized with Ca and P or F ions, with and without silver deposition. The chemical composition, surface topography, roughness (Ra), and surface free energy were evaluated before and after the surface modifications (anodizing). Adhesion and biofilm formation on saliva-coated discs by primary colonizing species (Streptococcus sanguinis, Streptococcus gordonii, Actinomyces naeslundii) and a periodontal pathogen (Porphyromonasgingivalis) were assessed. The surfaces of titanium alloys were modified after anodizing with volcano-shaped micropores with Ca and P or nanosized with F, both with further silver deposition. There was an increase in the Ra values after micropores formation; CaP surfaces became more hydrophilic than other surfaces, showing the highest polar component. For adhesion, no difference was detected for S. gordonii on all surfaces, and some differences were observed for the other three species. No differences were found for biofilm formation per species on all surfaces. However, S. gordonii biofilm counts on distinct surfaces were lower than S. sanguinis, A. naeslundii, and P. gingivalis on some surfaces. Therefore, anodized Ti-35Nb-7Zr-5Ta affected microbial adhesion and subsequent biofilm, but silver deposition did not hinder the colonization of these microorganisms.

9.
Am J Orthod Dentofacial Orthop ; 159(1): 86-96, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33223377

RESUMO

INTRODUCTION: Computer-aided design and manufacturing (CAD-CAM) systems have assisted orthodontists to position brackets virtually. The purpose of this study was to evaluate if a CAD-CAM system could predict the orthodontic treatment outcome of patients with Angle Class I malocclusion with mild crowding or spacing and with no need for orthodontic extraction. METHODS: Using the American Board of Orthodontics Cast-Radiograph Evaluation (ABO-CRE) and color map superimposition, the treated occlusion was compared with the virtual final occlusion of 24 young adults with Class I occlusion. Using eXceed software (eXceed, Witten, Germany), we created the final occlusion prediction for each patient (virtual set up group). A digital model of the final occlusion of each patient was created (treated occlusion group). ABO-CRE score was used to compare groups. In addition, a color map was created for all subjects to access the mean and range values between the virtual set up model and treated occlusion model of each patient. Random and systematic errors were calculated. In addition, chi-square and t test were used. RESULTS: Comparisons between virtual set up occlusion and treated occlusion showed statistically significant differences in 3 out of 7 measurements: interproximal contact score was larger for treated than virtual occlusion (0.45 mm and 0.04 mm, respectively), and the treated occlusion showed larger values than the virtual occlusion for occlusal contacts (14.13 mm and 7.62 mm, respectively) and overjet (7.37 mm and 0.66 mm, respectively). Although the treated occlusion showed a larger score than the virtual occlusion (50.41 mm and 34.58 mm, respectively), there is no significant difference between both. Root angulation decreased (from 1.95 ± 1.29 to 0.65 ± 0.71) because of the treatment. CONCLUSIONS: ABO-CRE overall score presents no difference between groups. In addition, CAD-CAM setup occlusion closely predicts the final teeth alignment and leveling with interarch relationships showing less ABO-CRE score deduction.


Assuntos
Má Oclusão Classe I de Angle , Má Oclusão , Sobremordida , Desenho Assistido por Computador , Humanos , Má Oclusão Classe I de Angle/diagnóstico por imagem , Má Oclusão Classe I de Angle/terapia , Modelos Dentários , Adulto Jovem
10.
Braz Dent J ; 31(6): 657-663, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33237238

RESUMO

The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; a=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings.


Assuntos
Revestimento de Dentadura , Hipoclorito de Sódio , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Retenção de Dentadura , Teste de Materiais , Resistência à Tração
11.
Braz. dent. j ; 31(6): 657-663, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132344

RESUMO

Abstract The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; a=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings.


Resumo O objetivo do estudo foi avaliar o efeito de soluções higienizadoras sobre a força de retenção de encaixes do tipo o-ring. Foram avaliadas quatro soluções: Cepacol (C); Cepacol com flúor (CF), Listerine (L), hipoclorito de sódio 0,05% (HS) e água deionizada (controle/AD) em o-rings de nitrilo. Matrizes contendo dois implantes e pilares e espécimes em acrílico com as cápsulas metálicas foram obtidas e divididas entre os grupos. Foi realizada a simulação de 90 imersões noturnas (8 h), sendo obtido o valor da resistência à tração no início e a cada 30 dias (T0, T1, T2 e T3) por meio da máquina de ensaios mecânicos (n=6). Microscopia eletrônica de varredura (MEV) foi utilizada para análise de danos na superfície do o´ring após a imersão (n=1). Para análise estatística dos resultados foi utilizada análise de variância (ANOVA) e múltiplas comparações com ajuste de Bonferroni (poder do teste=1,000; a=0,05). Houve diferença significante para os fatores tempo (p<0,001), solução (p<0,001) e para interação de tempo × solução (p<0,001). Considerando-se os tempos de cada solução, apenas AD não apresentou perda significativa de retenção ao longo do tempo. Comparando as soluções em cada momento, não houve diferença entre as soluções em T0. A partir de T1, CF e HS propiciaram menor retenção quando comparados à AD (p <0,005). Através do MEV foi possível observar alterações nas superfícies dos o-rings de nitrilo imersos em CF e HS. O Cepacol com flúor e hipoclorito de sódio devem ser evitados devido à ação deletéria nos o-rings.


Assuntos
Hipoclorito de Sódio , Resistência à Tração , Teste de Materiais , Retenção de Dentadura , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Revestimento de Dentadura
12.
Dental Press J Orthod ; 25(1): 28-35, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32215475

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effect of the Yd:YAG laser irradiation on orthodontic bracket base surface. Shear bond strength (SBS) values and sites of the bonding failure interfaces were quantified. METHODS: Brackets were divided into two groups: OP (One Piece - integral sandblast base) and OPL (One Piece - laser irradiation). The brackets were randomly bonded on an intact enamel surface of 40 bovine incisors. The SBS tests were carry out using a universal test machine. A stereomicroscopy was used to evaluate the adhesive remnant index (ARI), and surface characterization was performed by scanning electron microscopy (SEM). Student's t-test was used to compare the SBS between the two groups (p< 0.05). Frequencies and chi-square analysis were applied to evaluate the ARI scores. RESULTS: OPL group showed higher value (p< 0.001) of SBS than OP group (43.95 MPa and 34.81 MPa, respectively). ARI showed significant difference (p< 0.001) between OPL group (ARI 0 = 100%) and OP group (ARI 0 = 15%). SEM showed a higher affinity between the adhesive and the irradiated laser base surface. CONCLUSIONS: Yd:YAG laser irradiation on bracket base increased SBS values, showing that bonding failure occurs at the enamel/adhesive interface. Laser-etched bracket base may be used instead of conventional bases in cases where higher adhesion is required, reducing bracket-bonding failure.


Assuntos
Colagem Dentária , Lasers de Estado Sólido , Braquetes Ortodônticos , Animais , Bovinos , Humanos , Metais , Resistência ao Cisalhamento , Propriedades de Superfície
13.
Dental press j. orthod. (Impr.) ; 25(1): 28-35, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1089830

RESUMO

ABSTRACT Objective: The purpose of this study was to evaluate the effect of the Yd:YAG laser irradiation on orthodontic bracket base surface. Shear bond strength (SBS) values and sites of the bonding failure interfaces were quantified. Methods: Brackets were divided into two groups: OP (One Piece - integral sandblast base) and OPL (One Piece - laser irradiation). The brackets were randomly bonded on an intact enamel surface of 40 bovine incisors. The SBS tests were carry out using a universal test machine. A stereomicroscopy was used to evaluate the adhesive remnant index (ARI), and surface characterization was performed by scanning electron microscopy (SEM). Student's t-test was used to compare the SBS between the two groups (p< 0.05). Frequencies and chi-square analysis were applied to evaluate the ARI scores. Results: OPL group showed higher value (p< 0.001) of SBS than OP group (43.95 MPa and 34.81 MPa, respectively). ARI showed significant difference (p< 0.001) between OPL group (ARI 0 = 100%) and OP group (ARI 0 = 15%). SEM showed a higher affinity between the adhesive and the irradiated laser base surface. Conclusions: Yd:YAG laser irradiation on bracket base increased SBS values, showing that bonding failure occurs at the enamel/adhesive interface. Laser-etched bracket base may be used instead of conventional bases in cases where higher adhesion is required, reducing bracket-bonding failure.


RESUMO Objetivo: O objetivo do presente estudo foi avaliar o efeito da aplicação do laser Yd:YAG sobre a superfície metálica da base de braquetes ortodônticos, a resistência da colagem ao cisalhamento (RU) e os locais das falhas nas interfaces adesivas. Métodos: Os braquetes foram divididos em dois grupos, de acordo com o tipo de base: OP (One Piece - monobloco, base jateada) e OPL (One Piece - monobloco, base irradiada a laser). Foram selecionados 40 incisivos bovinos hígidos para a colagem de braquetes na superfície do esmalte. Os testes de RU foram realizados por meio de uma máquina de ensaio universal EMIC DL1000. O Índice de Adesivo Remanescente (ARI) e a caracterização das superfícies foram realizados empregando-se estereomicroscópio e microscópio eletrônico de varredura (MEV). O teste t de Student foi aplicado para comparar a RU entre os dois grupos (p< 0,05). O ARI foi avaliado por meio da análise de Frequência e teste do Qui-quadrado. Resultados: O grupo OPL obteve maiores valores de RU (p<0,001) do que o grupo OP (43,95 MPa e 34,81 MPa, respectivamente), e o ARI obteve diferença significativa (p<0,001) entre os grupos OPL (ARI 0 = 100%) e OP (ARI 0 = 15%). A análise proveniente do MEV mostrou alta interação adesiva entre a resina e a superfície metálica da base irradiada pelo feixe de laser. Conclusões: A irradiação com laser Yd:YAG sobre a superfície da base de braquetes metálicos aumentou os valores da RU, demonstrando que as falhas adesivas ocorreram na interface esmalte/adesivo. O uso de braquetes modificados com irradiação a laser pode ser adotado como alternativa aos braquetes com bases convencionais nos casos em que uma maior retentividade for requerida para reduzir as falhas de adesividade.


Assuntos
Humanos , Animais , Colagem Dentária , Braquetes Ortodônticos , Lasers de Estado Sólido , Propriedades de Superfície , Bovinos , Resistência ao Cisalhamento , Metais
14.
Biofouling ; 35(2): 173-186, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30935231

RESUMO

The chemical composition of biomaterials can drive their biological responses; therefore, this in vitro study aimed to evaluate the proteomic profile of the salivary pellicle formed on titanium (Ti) alloys containing niobium (Nb) and zirconium (Zr). The experimental groups consisted of Ti35NbxZr (x = 5 and 10 wt%) alloys, and commercially pure titanium (cpTi); titanium aluminium vanadium (Ti6Al4V) alloys were used as controls. The physical and chemical characteristics of the Ti materials were analysed. The proteomic profile was evaluated by liquid chromatography coupled with tandem mass spectrometry. Bacterial adhesion (2 h) of mixed species (Streptococcus sanguinis and Actinomyces naeslundii) was investigated as colony-forming units (n = 6). This paper reports the finding that salivary pellicle composition can be modulated by the composition of the Ti material. The Ti35NbxZr group showed a significant ability to adsorb proteins from saliva, which can favour interactions with cells and compatibility with the body.


Assuntos
Ligas/química , Película Dentária/química , Nióbio/química , Proteoma/análise , Proteínas e Peptídeos Salivares/análise , Titânio/química , Zircônio/química , Adsorção , Aderência Bacteriana , Materiais Biocompatíveis/química , Proteômica
15.
Ortho Sci., Orthod. sci. pract ; 12(48): 113-119, 2019. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-1048713

RESUMO

Resumo Introdução: Os sistemas CAD/CAM auxiliam ortodontistas na confecção de alinhadores estéticos e na colagem indireta (posicionamento virtual de bráquetes) em modelos digitais tridimensionais. Este estudo avaliou a precisão e validade do software eXceedTM. Métodos: Vinte modelos de gesso de pacientes foram digitalizados utilizando um escâner de mesa e os arquivos obtidos foram convertidos em estereolitografia pelo software OrthoAnalyserTM. Utilizando os modelos de gesso e digital, seis medidas foram aferidas: Largura Intermolares (LM), Largura Intercaninos (LC), Comprimento do Arco posterior (CA), Diâmetro da Coroa do Pré-Molar (DP), Altura da Coroa do Canino (AC) e Overjet (OJ). Os erros sistemáticos e aleatórios foram avaliados em análises das réplicas das mensurações. As diferenças foram avaliadas usando o teste t de Student. Os erros aleatórios foram quantificados usando o erro do método (V(Sd2/2n) e o Coeficiente de Correlação Intraclasse (ICC). Resultados: Duas das medidas das réplicas em modelos digitais (CA) e de gesso (LC) demostraram erros sistemáticos estatisticamente significativos. O ICC variou de 0,916 a 0,997. Os erros do método foram todos inferiores a 0,41 mm (0,22 mm). Os gráficos de Bland-Altman mostraram que as diferenças de repetitividade entre os dois métodos estavam dentro dos limites de concordância. Os valores DP (0,253 mm), LC (0,396 mm), AC (0,314 mm) e CA (0,359 mm) foram maiores em modelos de gesso do que nos modelos digitais. Conclusão: As medidas realizadas em ambos os métodos foram confiáveis e reprodutíveis, e as medidas dos modelos de gesso foram ligeiramente maiores do que os dos modelos digitais correspondentes (AU)


Abstract Introduction: CAD/CAM systems help orthodontists in the production of aesthetic aligners and in indirect bonding (virtual bracket positioning) in three-dimensional digital models. This study evaluated the accuracy and validity of the eXceedTM 3D software (Roosikrantsi, Tallinn, Estonia). Methods: Twenty patient plaster models were digitized by a desktop scanner, and the files obtained were converted to stereolithography by OrthoAnalyserTM software. Using the cast and digital models, six measurements were performed: Intermolar Width (LM); Intercanine Width (LC); Posterior Arch Length (CA); Premolar Crown Diameter (DP); Canine Crown Hight (AC) and Overjet (OJ). Intra-observer systematic differences between the replicates were described with mean absolute differences and standard errors (SE); differences were assessed using a paired Students t test. Random errors were quantified using the method error statistic (V[Sd2/2n]) and Intraclass Correlation Coefficient (ICC). Differences between methods was evaluated using Students t test. Results: Two of the measurements of the replicas in the digital model (CA) and in the plaster model (LC) showed statistically significant systematic errors. The ICC ranged from 0.916 to 0.997. The method errors were all less than 0.41 mm (0.22 mm). Bland-Altman plots showed that the differences of repeatability between the two methods were within the limits of agreement. The values DP (0.253 mm), LC (0.396 mm), AC (0.314 mm) and CA (0.359 mm) were higher in plaster models than in digital models. Conclusion: The measurements performed in both methods were reliable and reproducible, and plaster models measurements were slightly higher than those of the corresponding digital models. (AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Ortodontia , Tecnologia Odontológica , Desenho Assistido por Computador , Modelos Dentários , Precisão da Medição Dimensional
16.
Ortho Sci., Orthod. sci. pract ; 12(47): 145-151, 2019. tab, ilus
Artigo em Inglês | BBO - Odontologia | ID: biblio-1023059

RESUMO

Os sistemas CAD/CAM, incluindo o sistema eXceed™, possibilitam aos ortodontistas a realização de diagnóstico, planejamento de casos clínicos e posicionamento virtual de bráquetes. A posição de cada acessório, determinada pelo software, é transferida para o modelo tridimensional do paciente sobre o qual um dispositivo de transferência para colagem indireta (CI) de bráquetes é produzido. A CI permite uma melhoria na precisão da colagem de acessórios ortodônticos, diminuindo o tempo e o custo do tratamento devido a uma menor necessidade de dobras de finalização e reposicionamento de bráquetes. O caso clínico apresentado tem o objetivo de apresentar um tratamento ortodôntico utilizando o método de CI com posicionamento virtual de bráquetes idealizado pelo sistema eXceed™. O posicionamento dos bráquetes programado pelo sistema eXceed™ permitiu um posicionamento "ideal" dos dentes dispensando a implementação de dobras de finalização e proporcionando uma oclusão equilibrada. Essa nova tecnologia demonstrou ser eficiente e eficaz, e o setup ortodôntico fornecido pelo sistema ficou acordante com o resultado final do tratamento ortodôntico (AU)


CAD/CAM systems, including the eXceed™ system, allow orthodontists to perform diagnosis, treatment plan, and brackets virtual positioning. The positioning of each bracket, determined by the software, is transferred to a tridimensional patient model enabling to build an indirect bonding (IB) tray. IB allows improvement in the ideal bracket positioning, decreasing treatment time and cost due to less detailed finishing bends and/or bracket repositioning. The clinical case report purpose is to present an orthodontic treatment using IB with virtual bracket positioning using eXceed™ system. The bracket virtual positioning from eXceed™ system allowed an ideal final teeth positioning eliminating detailed finishing bends and reaching the ideal occlusion as planned. This new technology has shown to be efficient and effective, and the virtual tridimensional orthodontic setup has been in agreement with the final treatment occlusion (AU)


Assuntos
Humanos , Masculino , Adulto , Aparelhos Ortodônticos , Ortodontia Corretiva , Desenho Assistido por Computador
17.
Clin Implant Dent Relat Res ; 20(3): 274-279, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29380490

RESUMO

BACKGROUND: Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process. PURPOSE: The purpose of the present in vitro study was to evaluate the mechanical behavior of geometric changes in the apex region of dental implants. METHODS: Thirty-five cylindrical dental implants (Titamax Ti; Neodent) were machined at the apical third to reproduce the experimental groups: without apical cut (Wc), apical bi-split cut, apical tri-split cut, apical quadri-split cut (Qs). One (control group) (Titamax Ti Ex) (n = 7) without any modifications was added. The implants had the same final dimensions (4.1 x 11 mm2 ). All implants were inserted into artificial bone blocks and were evaluated by insertion torque and resonance frequency by ISQ values (Osstell). Two-tailed analysis of variance (One-way ANOVA) and Tukey's post-test (P < .05). RESULTS: Control and Qs implants showed a significant increase of the insertion torque (P < .001). For the resonance frequency, Wc and (control) implants had the greatest ISQ values. However, there's no significant difference between (control) and Qs for the ISQ values (P < .001). CONCLUSION: Within the limitations of the present study, the proposed geometries at the apical third of dental implants greatly influenced its insertion torque and primary stability in vitro.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Retenção em Prótese Dentária , Torque , Vibração , Fenômenos Químicos , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Fenômenos Geológicos , Técnicas In Vitro , Osseointegração , Propriedades de Superfície , Titânio
18.
Dent Mater ; 33(11): 1244-1257, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28778495

RESUMO

OBJECTIVE: The aim of this study was to develop binary and ternary titanium (Ti) alloys containing zirconium (Zr) and niobium (Nb) and to characterize them in terms of microstructural, mechanical, chemical, electrochemical, and biological properties. METHODS: The experimental alloys - (in wt%) Ti-5Zr, Ti-10Zr, Ti-35Nb-5Zr, and Ti-35Nb-10Zr - were fabricated from pure metals. Commercially pure titanium (cpTi) and Ti-6Al-4V were used as controls. Microstructural analysis was performed by means of X-ray diffraction and scanning electron microscopy. Vickers microhardness, elastic modulus, dispersive energy spectroscopy, X-ray excited photoelectron spectroscopy, atomic force microscopy, surface roughness, and surface free energy were evaluated. The electrochemical behavior analysis was conducted in a body fluid solution (pH 7.4). The albumin adsorption was measured by the bicinchoninic acid method. Data were evaluated through one-way ANOVA and the Tukey test (α=0.05). RESULTS: The alloying elements proved to modify the alloy microstructure and to enhance the mechanical properties, improving the hardness and decreasing the elastic modulus of the binary and ternary alloys, respectively. Ti-Zr alloys displayed greater electrochemical stability relative to that of controls, presenting higher polarization resistance and lower capacitance. The experimental alloys were not detrimental to albumin adsorption. SIGNIFICANCE: The experimental alloys are suitable options for dental implant manufacturing, particularly the binary system, which showed a better combination of mechanical and electrochemical properties without the presence of toxic elements.


Assuntos
Ligas Dentárias/síntese química , Implantes Dentários , Nióbio/química , Titânio/química , Zircônio/química , Albuminas/química , Materiais Biocompatíveis/síntese química , Módulo de Elasticidade , Eletroquímica , Dureza , Teste de Materiais , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Espectrometria por Raios X , Difração de Raios X
19.
Dental Press J Orthod ; 20(6): 89-96, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26691975

RESUMO

OBJECTIVE: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. METHODS: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. RESULTS: All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. CONCLUSION: The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.


Assuntos
Estresse Mecânico , Ligas Dentárias , Teste de Materiais , Fios Ortodônticos , Titânio
20.
Dental press j. orthod. (Impr.) ; 20(6): 89-96, Nov.-Dec. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-770272

RESUMO

Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. Results: All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. Conclusion: The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.


Resumo Objetivo: avaliar os sistemas de força produzidos por quatro marcas de fios de -Ti, dobrados em formas complexas. Métodos: quarenta molas T-Loop (TLS) dobradas à mão, confeccionadas a partir de fios de -Ti, calibre 0,017" x 0,025", foram aleatoriamente divididas em quatro grupos, de acordo com a marca do fio: TMA (G1), BETA FLEXY (G2), BETA III Wire (G3) e BETA CNA (G4). Forças e momentos foram registrados por um transdutor de momento - acoplado a um extensômetro digital, adaptado a uma máquina de ensaios -, a cada 0,5mm de desativação, a partir de 5mm da ativação inicial. A proporção momento-força (M/F), a sobreposição das extensões verticais das TLSs e a relação carga-deflexão (C/D) também foram calculadas. Para completar os resultados, o módulo de Young (MY) de cada fio foi determinado pelo declive no gráfico de carga-deflexão em um ensaio de tração. Ademais, a composição química da superfície foi avaliada por um espectrômetro de fluorescência de raios X por energia dispersiva. Resultados: todos os grupos, exceto o G2, produziram níveis de força semelhantes, inicialmente. O G3 produziu as maiores taxas de C/D, enquanto G1 e G4 tiveram quantidades similares de sobreposição das extensões verticais das TLSs em posição neutra. G1 e G3 geraram os mais altos níveis de momentos, enquanto G2 e G3 produziram os mais altos índices de M/F. Os fios -Ti do G3 produziram o maior MY, e todos os grupos apresentaram composição semelhante, exceto G2. Conclusão: os quatro fios de beta-titânio analisados produziram diferentes sistemas de forças, quando utilizados para formas mais complexas, devido ao fato de que cada fio responde de forma diversa à confecção de dobras.


Assuntos
Estresse Mecânico , Fios Ortodônticos , Titânio , Teste de Materiais , Ligas Dentárias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...